Electric Drives and Controls - Product Catalog
|
| Rexroth PSI 6500 - MF Inverter |
 |

|
 |
MF inverter 9 - 120 kA, water-cooled, 400 - 480 V, 50/60 Hz, preferable for the connection of PSG 6000 transformers, with integrated control functionality, rated current up to 660 A (thermic continuous current), I/O board of choice:
- parallel
- Profibus
- Interbus wire
- Interbus fiber optic
- Interbus fiber optic OPC
- DeviceNet
- V24
- Master/Slave
Master/Slave Concept

The PSI 6500 inverter can be used for performance improvement in a master/slave setup. Up to 3 devices can then be connected in parallel, by connecting each inverter with one or more identical transformers.

The transformers can then be secondarily powered in parallel with simple symmetry, to achieve triple performance from a single device. The devices are the same from a hardware perspective. The slave or master function is selected and activated using parameters when the connection cable is plugged in.
|
|
 |
Product Brochure (PDF)
Master/Slave Concept Brochure (PDF)
Rolled Seam Welding Brochure (PDF)

|
| Construction Type | built-in 3-phase, medium-frequency inverter module | | Welding Control | integrated | | I/O Interface | plug-in slot for parallel and serial I/O, and fieldbus interface | | Quality Module | plug-in slot prepared | | Protection | IP 20 | | Ambient Temperature | max. 55° Celsius | | Cooling | L1/L2: air max.45° C - W1: water 4 liters/min.; max 30° C | | Temperature Monitoring | integrated | | Storage Temperature | -20° C to 70° C | | Corrosion | The ambient air must be free of higher concentrations of acids, bases, corrosive substances, salt and metal vapors. | | Degree of Humidity | humidity class F acc. to DIN 40040; 20° C at 90% relative humidity; 40° C at 50% relative humidity (acc. to VDE 0113); condensation of the converter is unacceptable. | | Air Pressure | within range up to 2000m above sea level | | Supply Voltage Connection, grounded TN or TT grid | L1/W1: 400V -20% to 480V -10%, 50/60 Hz; L2: 489V -20% to 690V -10%; 50/60Hz | | Supply Voltage: Central Unit; I/O Interface | 24V=, min. 19V= to max. 30V= acc. to EN 61131-2 | | Pulse Frequency | 1kHz | | Overvoltage Protection | metal oxide varistor |

|
| Max. Thermic Continuous Current | 110A | 110A | 220A | 110A | 110A | 660A with cabinet cooling; 330A without cabinet cooling | | Max. Output Current | 400A | 400A | 1200A | 800A | 800A | 2400A | | Max. Output Current, Transformer-Dependent | 20kA | 20kA | 54kA | 36kA | 36kA | 120kA | | Electr. Connection Max. | 50 mm2 | 50 mm2 | HDFK; max. 95 mm2 | 50 mm2 | 50 mm2 | terminal ends, M10 screw connection | | Connection Cross-Section | 35 mm2 | 35 mm2 | 95 mm2 | 35 mm2 | 35 mm2 | 2 to 4 cables per 120 mm2 | | Control Cabinet Basic Losses | 100W | 69W | 69W | 100W | 69W | 100W | | Max. Cooling Losses; Discharged via External Ventilator | 360W | 420W | 700W | 360W | 420W | 4400W | | Cabinet Losses at Max. Performance | 200W | 110W | 210W | 200W | 110W | 850W | | Weight | 21kg | 25kg | 56kg | 21kg | 25kg | 70kg, mech. separable |
|
|
|
|
|
|
|
|